The Astra300 puts the sophistication and simplicity of a touch screen in the palm of your hand. Enter data, test patients, and send and print reports with precision and ease. Easily report your choice of up to 40 spirometry test parameters, all measured accurately and precisely.
Easily report your choice of up to 40 spirometry test parameters, all measured accurately and precisely with the highly sophisticated Astra300 Spirometer. Using the bright and sensitive touchscreen, you can easily access multifunctional capabilities and view both graphic and tabular data.
Entering patient data, patient testing and reporting couldn't be easier. Exporting test data to a printer or PC via USB is quickly accomplished with just a few stylus taps on the touchscreen. A Bluetooth-to-PC module is available as as option for truly wireless communication.
Features:
AstraPro spirometry software included
Bright, sensitive touchscreen
Multi-functional capabilities
View both graphic and tabular data
Easy to use
Export test data to a printer or PC via USB
NIOSH and SSA Guidelines Compliant
Choice of 14 Predicted Sets
Unique flow triggers allows tidal breathing for easier, more accurate testing
Automated maneuver acceptability
assures accurate results
Highly configurable program
Choice of custom or pre-set programs
includes latest NLHEP guidelines
AccuFloDigital Turbine Transducer
Optional Pulse Oximetry
Optional Bluetooth-to-Printer - Speedy wireless communication
Specifications:
Forced Parameters Measured
Forced Vital Capacity: FVC, FEV.5, FEV1, FEV3, FEV6, FEV1/FVC, FEV1/FEV6, FEV.5/FVC, FEV3/FVC, PEF, FEF25, FEF50, FEF75, FEF25-75, FEF 75-85, FET, FET25-75, FEV1/FEV.5, FEV1/PEF, FIF50, FIVC, FIV1, FIV1/FVC, FEV1/FIV1,PIF, MTT, PEF/PIF, BEV, Lung Age
MVV: Br/min
Relaxed Parameters Measured
VC: VC, TV, ERV, IRV, IC, Ti, Te, Tt, Ti/Tt
Maneuvers per patient: 5 total; best test and last test highlighted
Interpretation: Selectable – Kory, Miller, ATS, NLHEP (Ferguson)
Predicted sets: Selectable – 14 Total
Ethnic correction: Selectable – % Actual, Caucasian, Hispanic, AfroAmerican
Language: Selectable – English or Spanish
Measurement Scale (BTPS)
Flow range: 0–16 L/sec
Volume: 0–10 L
Measurement method: Infrared Interruption via Digital Turbine
Dynamic flow resistance:
Precision of Measurements (BTPS)
At highest volume: +/- 3% or 50 mL
At highest flow: +/- 5% or 150 mL
Time related precision: .5%
Volume resolution:
Sampling frequency: 50 Hz
Hardware Specifications
Storage capacity: 1000+ study database
Keyboard: Alphanumeric LCD touchscreen
Communication: USB to printer and PC, RS232
Optional: Bluetooth to PC
Dimensions: 5.75" x 3.25" x 4.0"
Power supply: 2 x 1.5 DC Alkaline or NiMH batteries
Weight: 9 oz (250 g)
29-5300 29-5301-050